EasyManua.ls Logo

Dasan V5808 - BPDU Transmission Rate; Administrational Key; Port Priority

Dasan V5808
814 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual UMN:CLI
V5808
285
8.2.2.6 BPDU Transmission Rate
Member port transmits BPDU with its information. For the V5808, it is possible to
configure the BPDU transmission rate, use the following command.
Command
Mode
Description
lacp port timeout PORTS {short |
long}
Bridge
Configures BPDU transmission rate:
PORTS: select the port number.
short: short timeout (1 sec)
long: long timeout (30 sec: default)
To clear BPDU transmission rate, use the following command (clear means long timeout).
Command
Mode
Description
no lacp port timeout PORTS
Bridge
Clears BPDU transmission rate of configured member
port, select the port number.
8.2.2.7 Administrational Key
Member port of LACP has key value. All member ports in one aggregator have same key
values. To make the aggregator consisted of specified member ports, configure the
different key value with the key value of another port.
Command
Mode
Description
lacp port admin-key PORTS <1-
15>
Bridge
Configures the key value of a member port:
PORTS: select the port number.
1-15: key value (default: 1)
To delete the key value of a specified member port, use the following command.
Command
Mode
Description
no lacp port admin-key PORTS
Bridge
Deletes the key value of a specified member port,
select the member port number.
8.2.2.8 Port Priority
To configure priority of an LACP member port, use the following command.
Command
Mode
Description
lacp port priority PORTS <1-
65535>
Bridge
Sets the LACP priority of a member port, select the
port number. (default: 32768)
To delete the configured port priority of the member port, use the following command.
Command
Mode
Description
no lacp port priority PORTS
Bridge
Deletes the configured port priority of a selected

Table of Contents