User Manual UMN:CLI
V5808
285
8.2.2.6 BPDU Transmission Rate
Member port transmits BPDU with its information. For the V5808, it is possible to
configure the BPDU transmission rate, use the following command.
lacp port timeout PORTS {short |
long}
Configures BPDU transmission rate:
PORTS: select the port number.
short: short timeout (1 sec)
long: long timeout (30 sec: default)
To clear BPDU transmission rate, use the following command (clear means long timeout).
no lacp port timeout PORTS
Clears BPDU transmission rate of configured member
port, select the port number.
8.2.2.7 Administrational Key
Member port of LACP has key value. All member ports in one aggregator have same key
values. To make the aggregator consisted of specified member ports, configure the
different key value with the key value of another port.
lacp port admin-key PORTS <1-
15>
Configures the key value of a member port:
PORTS: select the port number.
1-15: key value (default: 1)
To delete the key value of a specified member port, use the following command.
no lacp port admin-key PORTS
Deletes the key value of a specified member port,
select the member port number.
8.2.2.8 Port Priority
To configure priority of an LACP member port, use the following command.
lacp port priority PORTS <1-
65535>
Sets the LACP priority of a member port, select the
port number. (default: 32768)
To delete the configured port priority of the member port, use the following command.
no lacp port priority PORTS
Deletes the configured port priority of a selected