UMN:CLI User Manual
V5808
208
To specify an errored window size and threshold according to the event type, use the
following command.
oam efm link-monitor frame
window <10-600> threshold <0-
65535> PORTS
Specifies the window size and threshold in case of
frame event.
10-600: window size (unit: 100msec, default:1 second)
0-65535: threshold value (default:1)
oam efm link-monitor frame-
period window <1000-
200000000> threshold <0-
65535> PORTS
Specifies the window size and threshold in case of
frame-period event.
1000-200000000: window size (default: 1000000 pkts)
0-65535: threshold value (default:1)
oam efm link-monitor symbol-
period window <1-1000000>
threshold <0-65535> PORTS
Specifies the window size and threshold in case of
symbol-period event.
1-1000000: window size (default: 625 million)
0-65535: threshold value (default:1)
oam efm link-monitor frame-
seconds-summary window <10-
900> threshold <0-900> PORTS
Specifies the window size and threshold in case of
frame-seconds-summary error event.
10-900: window size (default: 60 seconds)
0-900: threshold value (default:1)
To clear the collected statistics of EFM OAM link monitoring, use the following command.
clear oam efm link-monitor stats PORTS
Clears the collected statistics of EFM
OAM link monitoring.
PORTS: port number
To configure how to handle the event notifications that the switch is received, use the
following command.
oam efm link-monitor action
syslog PORTS
Generates a syslog message when event notifications
are received.
PORTS: port number
oam efm link-monitor action
snmp-trap PORTS
Generates a snmp trap message when event
notifications are received.
PORTS: port number
7.6.3 EFM OAM Mode
To configure EFM OAM mode, use the following command.
oam efm mode {active | passive}
Configures the mode of EFM OAM.