UMN:CLI User Manual
V5808
660
For the details of how to create and configure the VoIP service, see 12.4.6 VoIP Service
Configuration (POTS UNI).
12.2.10.2 ONT Termination ID Configuration
The attribute specifies the base string for the MGC (H.248) physical termination ID(s) for
the ONT. This string is intended to uniquely identify an ONT. Vendor-specific termination
identifiers (i.e. port IDs) are optionally added to this string to uniquely identify a
termination on a specific ONT.
To configure the termination ID on POTS interface of ONT, use the following command.
onu voip-mgc ONU-ID
termination-id pots POTS_NUM
TERMINATION_ID
Specifies the termination ID on POTS interface of ONT.
ONU-ID: ONU ID or serial number
POTS_NUM: POTS number
TERMINATION_ID: termination ID
no onu voip-mgc ONU-ID
termination-id pots POTS_NUM
Deletes the configured termination ID.
12.2.11 ONU Port Configuration
12.2.11.1 UNI Ethernet Port Configuration
To configure the UNI Ethernet port of ONU, use the following command.
onu port-config ONU-IDs uni eth
UNI-PORTs medium-mode {mdi |
mdi-x | auto}
Configures the medium mode of ONU UNI Ethernet
port.
ONU-ID: 1-128 or ONU serial number
UNI-PORT: ONU UNI port number
mdi: MDI mode
mdi-x: MDIX mode
auto: automatically
onu port-config ONU-IDs uni eth
UNI-PORTs speed {auto | 1000 |
100 | 10} duplex {auto | full | half}
Configures the speed and duplex mode of ONU UNI
Ethernet port.
onu port-config ONU-IDs uni eth
UNI-PORTs power-control
Enables/disables the Power over Ethernet (PoE) port
on the specified ONU.