User Manual UMN:CLI
V5808
643
To display the configured flow control mode of an OLT, use the following command.
show olt flow-contorl [OLT-ID]
Shows the flow control information.
12.1.21 Transceiver Type Configuration
To configure the transceiver type of OLT, use the following command.
olt transceiver-type {fujitsu |
neophotonics | neophotonics-a |
hisense | optowiz | superxon |
wtd | sourcephotonics}
Configures the transceiver type of OLT port.
show olt transceiver-type
[OLT_ID]
Enable
Global
GPON
GPON-OLT
Shows the transceiver type of OLT.
12.1.22 Displaying OLT Information
To display GPON OLT information, use the following command.
Enable
Global
GPON
GPON-OLT
Shows the information of active/inactive GPON OLT
IDs.
The following is an example of displaying active/inactive OLT IDs of the V5808.
SWITCH(gpon)# show olt status
------------------------------------------------------------
OLT_ID | Status | Protect | Distance | FEC mode(DS/US)
------------------------------------------------------------
1 | Active | | 20 Km | enable/disable
2 | Active | | 20 Km | enable/disable
3 | Active | | 20 Km | enable/disable
4 | Active | | 20 Km | enable/disable
SWITCH(gpon)# show olt status 2
------------------------------------------------------------
OLT_ID | Status | Protect | Distance | FEC mode(DS/US)
------------------------------------------------------------
2 | Active | | 20 Km | enable/disable