To enable/disable the alarm notify activity, use the following command.
snmp notify-activity {enable |
disable}
Enables/disables the alarm notify activity.
(default: disable)
7.1.13.2 Alarm Severity Criterion
You can set an alarm severity criterion to make an alarm be shown only in case of
selected severity or higher. For example, if an alarm severity criterion has been set to
major, you will see only an alarm whose severity is major or critical.
To set an alarm severity criterion, use the following command.
snmp alarm-severity criteria
{critical | major | minor | warning
| intermediate}
Sets an alarm severity criterion.
(default: warning)
The order of alarm severity is critical > major > minor > warning > intermediate.
7.1.13.3 Default Alarm Severity
To set default alarm severity, use the following command.
snmp alarm-severity default
{critical | major | minor | warning
| intermediate}
Sets default alarm severity.
(default: minor)
7.1.13.4 Generic Alarm Severity
To set generic alarm severity, use the following command.
snmp alarm-severity admin-access-login {critical
| major | minor | warning | intermediate}
Sets severity of an alarm for admin-
access-login.
snmp alarm-severity auth-fail {critical | major |
minor | warning | intermediate}
Sets severity of an alarm for auth-fail.
snmp alarm-severity cli-history {critical | major |
minor | warning | intermediate}
Sets severity of cli history log.
snmp alarm-severity cold-start {critical | major |
minor | warning | intermediate}
Sets severity of an alarm for system
cold restart.
snmp alarm-severity cpu-load-over {critical |
major | minor | warning | intermediate}
Sets severity of an alarm for CPU load
high.
snmp alarm-severity dhcp-lease {critical | major |
Sets severity of an alarm for no more IP