74-2
Catalyst 4500 Series Switch, Cisco IOS Software Configuration Guide - Cisco IOS XE 3.9.xE and IOS 15.2(5)Ex
 
Chapter 74      Configuring Flexible NetFlow
VSS Environment
3. Configuration is performed on the VSS Active switch, which is synchronized to the VSS Standby 
switch.
4. Netflow show commands including Top Talkers, aggregate cache, and clear commands must be 
executed independently on VSS Active and Standby switch. The VSS Standby console will be 
available via remote console access from the VSS Active switch.
5. Supervisor Engine 8-E, Supervisor Engine 7-E, Supervisor Engine 7L-E, and Catalyst 4500X 
support a 100,000 entry hardware flow table. Both VSS Active and Standby switch have independent 
hardware flow tables of 100,000 entries. The hardware flow table is shared by all the flow monitors 
on a switch. To prevent one monitor from using all the flow table entries, the number of entries that 
it uses on a switch can be limited by the cache entries number command. This limit is per flow 
monitor, irrespective of the number of targets it is attached to.
The following example illustrates how to configure the flow monitor m1 cache to hold 1000 entries. 
With this configuration, interface gig 1/3/1 (on the VSS Active) can create a maximum of 1000 flows 
and interface gig 2/3/2 (on the VSS Standby) can create a maximum of 1000 flows:
flow exporter e1
    ! exporter specifies where the flow records are send to
    destination 20.1.20.4 
!
flow record r1
    ! record specifies packet fields to collect
    match ipv4 source address
    match ipv4 destination address
    collect counter bytes long
    collect counter packets long
    collect timestamp sys-uptime first
    collect timestamp sys-uptime last
!
flow monitor m1
    ! monitor refers record configuration and optionally exporter
    ! configuration. It specifies the cache size i.e. how many unique flow
    ! records to collect
    record r1
    exporter e1
    cache timeout active 60
    cache timeout inactive 30
    cache entries 1000
!interface GigabitEthernet 1/3/1
    ! layer2-switched allows collection of flow records even when the packet is  
    ! bridged
     ip flow monitor m1 layer2-switched input
!
interface GigabitEthernet 2/3/2
    ip flow monitor m1 input
!
6. Flow collection is supported on multiple targets (Port, VLAN, per-port per-VLAN (FNF can be 
enabled on a specific VLAN on a given port)) and on a port-channel (FNF is configured on the 
port-channel interface, rather than individual member ports). These targets can be on the VSS Active 
or on the VSS Standby. For example, if the target is a VLAN, it can consist of ports belonging to 
both switches. If there is ingress traffic in that VLAN on both switches, flows will be created in their 
independent flow caches. However, no Netflow configuration can be applied on the Virtual Switch 
Link (VSL) ports.
7. 64 unique flow record configurations are supported.
8. Flow QoS/UBRL and FNF cannot be configured on the same target. (For information on Flow-based 
QoS, see the section Flow-based QoS, page 44-10.)