77-19
Catalyst 4500 Series Switch, Cisco IOS Software Configuration Guide - Cisco IOS XE 3.9.xE and IOS 15.2(5)Ex
Chapter 77 Configuring Call Home
Alert Group Trigger Events and Commands
SYSLOG LOG_ALERT 6 Action must be taken immediately.
SYSLOG LOG_CRIT 5 Critical conditions.
SYSLOG LOG_ERR 4 Error conditions.
SYSLOG LOG_WARNING 3 Warning conditions.
SYSLOG LOG_NOTICE 2 Normal but signification condition.
SYSLOG LOG_INFO 1 Informational.
SYSLOG LOG_DEBUG 0 Debug-level messages.
Environmental Events related to power, fan, and environment sensing
elements, such as temperature alarms. (Sent to TAC.)
CLI commands executed:
show module
show environment
show logging
show power
show inventory
TEMP_FAILU
RE
TempHigh 5 The temperature of the chassis is above the normal
threshold.
TEMP_FAILU
RE
Critical Temp 5 The temperature of the chassis has risen above the
critical threshold.
TEMP_FAILU
RE
Shutdown Temp 5 The temperature of the chassis is very high and the
system will be shut down.
TEMP_FAILU
RE
Some Temp Sensors
Failed
3 Some of the temperature sensors have failed.
TEMP_FAILU
RE
All Temp Sensors
Failed
5 All temperature sensors have failed.
TEMP_RECO
VER
TempOk 5 The temperature of the chassis is normal.
POWER_FAIL
URE
PowerSupplyBad 5 A power supply has failed or has been turned off.
POWER_REC
OVERY
PowerSupplyGood 5 A failed power supply has been fixed.
POWER_FAIL
URE
PowerSupplyFanBad 3 A power supply fan has failed.
POWER_
RECOVERY
PowerSupplyFanGood 3 A failed power supply fan has been fixed.
POWER_REC
OVERY
PowerSupplyOutputInc
reased
3 A power supply output has increased.
POWER_FAIL
URE
PowerSupplyOutputDe
creased
3 A power supply output has decreased.
Table 77-3 Call Home Alert Groups, Events, and Actions (continued)
Alert Group
Call Home
Trigger Event Syslog Event Severity Description and CLI Commands Executed