14-20
Catalyst 4500 Series Switch, Cisco IOS Software Configuration Guide - Cisco IOS XE 3.9.xE and IOS 15.2(5)Ex
 
Chapter 14      Environmental Monitoring and Power Management
Power Management
PS2     PWR-C45-4200ACV   AC 4200W   good         good     good   
PS2-1                         110V   good         
PS2-2                         110V   good         
Power supplies needed by system    : 1
Power supplies currently available : 2
Power Summary                      Maximum
 (in Watts)              Used     Available
----------------------   ----     ---------
System Power (12V)        140        1360
Inline Power (-50V)         0        1850
Backplane Power (3.3V)      0          40
----------------------   ----     ---------
Total                     140 (not to exceed Total Maximum Available = 2100)
Here is the output after invoking this feature. The combined mode was indicated before 
Power supplies needed = 2 in the output of the show power command, combined mode is now indicated 
by the phrase Power supplies needed by system: 2 Maximum Inputs = 3.
Switch# show power
sh power
Power                                             Fan      Inline
Supply  Model No          Type       Status       Sensor   Status
------  ----------------  ---------  -----------  -------  -------
PS1     PWR-C45-4200ACV   AC 4200W   good         good     good   
PS1-1                         110V   good         
PS1-2                         110V   good         
PS2     PWR-C45-4200ACV   AC 4200W   good         good     good   
PS2-1                         110V   good         
PS2-2                         110V   good         
Power supplies needed by system    : 2 Maximum Inputs = 3 
Power supplies currently available : 2
Power Summary                      Maximum
 (in Watts)              Used     Available
----------------------   ----     ---------
System Power (12V)        140        2400
Inline Power (-50V)         0        2000
Backplane Power (3.3V)      0          40
----------------------   ----     ---------
Total                     140 (not to exceed Total Maximum Available = 2728)
Switch#
Here's another example of combined mode resiliency with 9000W power supply with a maximum of six 
active inputs, limited to 3 inputs:
Switch# show power
Power                                             Fan      Inline
Supply  Model No          Type       Status       Sensor   Status
------  ----------------  ---------  -----------  -------  -------
PS1     PWR-C45-9000ACV   AC 9000W   good         good     good
PS1-1                         220V   good
PS1-2                         220V   good
PS1-3                         220V   good
PS2     PWR-C45-9000ACV   AC 9000W   good         good     good
PS2-1                         220V   good
PS2-2                         220V   good
PS2-3                         220V   good
 
Power supplies needed by system    : 2 Maximum Inputs = 3