14. HDR Display (SER23)
310
HLG Upper Scale 1200% / 100%
Set the threshold for HLG.
When the function dial (F•D) is turned, the threshold values of HLG Scale 1200% and
100% change at the same ratio.
HLG Scale = 1200%
MAX FALL: 0,000 % (0.0 Nits) to 1,200 % (1000.0 Nits) to 2,000 % (1845.9 Nits)
MAX CLL: 0,000 % (0.0 Nits) to 1,200 % (1000.0 Nits) to 2,000 % (1845.9 Nits)
HLG Scale = 100%
MAX FALL: 0 % to 60 % to 100 %
MAX CLL: 0 % to 60 % to 100 %