3. SPECIFICATIONS
35
3.3.21 Focus Assist (SER25)
Detection Sensitivity LOW, MIDDLE, HIGH
Highlight Display Color WHITE, GREEN, BLUE, RED
Picture Luminance Level OFF, EMBOSS, 25%, 50%, 75%, 100%
3.3.22 CIE Chromaticity Diagram Display (SER22)
Display Standard CIE1931 (xy display), CIE1976 (u'v’ display)
Display Type Chromaticity diagram display, color temperature display
Display Mode
Chromaticity Diagram Display
Luminance display, color display
Color Temperature Display Luminance display
Colorimetry ITU-R BT.601(525), ITU-R BT.601(625), BT.709, DCI, ITU-R
BT.2020
Clipping
ON Clips negative values of the input signal to zero
OFF Displays negative values of the input signal according to ITU-
R BT.1361
Smoothing Displays by averaging data every two pixels
Accuracy ±0.005 (relative to the measurement coordinate value)
Chromaticity Diagram Display Scale
Triangle Select two from ITU-R BT.601 (525), ITU-R BT.601 (625),
ITU-R BT.709, DCI, and ITU-R BT.2020
User-defined Triangle Set a single user-defined triangle
Background Color sample, white background, black background
Sub scale Color temperature curve, grid (0.1 steps), white point (D65),
triangle name (each can be turned on or off)
Cursor Displays the cursor position in coordinates
Gamma ITU-R BT.709, user (1.5 to 3.0), HLG (SER23), PQ (SER23),
S-Log3 (SER23), C-Log (SER23), Log-C (SER23)