3. SPECIFICATIONS
25
3.3.12 Presets
Preset Saves panel settings (with a few exceptions)
Number of Presets 60
Preset Loading Method Front panel or remote connector (*1)
Copying All preset data can be copied from the instrument to a USB
memory device or from a USB memory device to the
instrument.
*1 The number of presets loaded from the remote connector can be 8 or 60.
3.3.13 Display
Number of simultaneously displayed SDI input signals
SD, HD, 3G-A, 3G-B-DL 2
3G(DL)-4K (SER28) 1
6G (SER28) 1
12G (SER28) 1
Display Mode
Single display Displays a single input signal
Simul Display Displays two input signals simultaneously
Alarm Indications
System Alarm Indication Displays an alarm when the fan malfunctions or when the
internal temperature is abnormal
Error Indication Displays an error when an receive signal error occurs
Display Layout
Multi Display Control the WFM/PIC and other display functions in multiple
areas from a single screen
Customized Layout (SER26)
Function Freely arrange the windows shown with the WFM, VECT, PIC,
AUDIO, STATUS, and EYE (LV5300/LV5300A/LV7300-SER02)
keys (one of each), and a window consisting of six displays
shown with MULTI
Display Format Displays up to two single link input signals in tiled, mixed, V
aligned, or H aligned mode.
Normal Mode Each display area is divided evenly.
Tiled Display The windows are divided into two quadrants.
Mixed Display The windows are cascaded.
V Aligned Display The windows are arranged top to bottom.
H Aligned Display The windows are arranged side by side.
Tile Mode The display contents arranged in the display are shown in two
quadrants per screen.
V Aligned Mode The display contents arranged in the display are shown in two
vertical divided windows per screen.
H Aligned Mode The display contents arranged in the display are shown in two
horizontally divided windows per screen.