19. Network Control
488
MIB
OID
SYNTAX
ACCESS
VALUE/RANGE
4 = c
5 = d
l40statusExtrefTBL
l40statusTBL.4
Aggregate
-
-
l40statusExtrefSel
l40statusExtrefTBL.3
INTEGER
R/W
1 = ext
2 = sdi
l40statusExtrefUserRef
l40statusExtrefTBL.1
INTEGER
R/WO
1 (fixed)
l40statusExtrefDefaultRef
l40statusExtrefTBL.2
INTEGER
R/WO
1 (fixed)
l40statusExtrefTiming
l40statusExtrefTBL.4
INTEGER
R/W
1 = legacy
2 = serial
l40statusAvPhaseTBL
l40statusTBL.5
Aggregate
-
-
l40statusAvPhaseScaleMax
l40statusAvphaseTBL.1
INTEGER
R/W
1 = scale-50ms
2 = scale-100ms
3 = scale-500ms
4 = scale-1000ms
5 = scale-2500ms
l40statusAvPhaseRefresh
l40statusAvphaseTBL.2
INTEGER
R/WO
1 (fixed)
l40statusAncTBL
l40statusTBL.6
Aggregate
-
-
l40statusAncDumpHold
l40statusAncTBL.1
INTEGER
R/W
1 = hold-hold
2 = hold-1s
3 = hold-3s
l40statusAncDumpMode
l40statusAncTBL.2
INTEGER
R/W
1 = hex
2 = binary
l40statusAncDumpSample
l40statusAncTBL.3
INTEGER
R/W
0 to 258
l40statusAncEdhDisp
l40statusAncTBL.4
INTEGER
R/W
1 = text
2 = dump
l40statusAncEdhMode
l40statusAncTBL.5
INTEGER
R/W
1 = hex
2 = binary
l40statusAncEdhSample
l40statusAncTBL.6
INTEGER
R/W
0 to 19
l40statusAncViewStream
l40statusAncTBL.7
INTEGER
R/W
1 = stream1
2 = stream2
l40statusAncPayloadStream
l40statusAncTBL.8
INTEGER
R/W
1 = stream1
2 = stream2
l40statusAncCtrlDisp
l40statusAncTBL.9
INTEGER
R/W
1 = text
2 = dump
l40statusAncCtrlMode
l40statusAncTBL.10
INTEGER
R/W
1 = hex
2 = binary
l40statusAncCtrlGroup
l40statusAncTBL.11
INTEGER
R/W
1 = group1
2 = group2
3 = group3
4 = group4
l40statusAncCtrlStream
l40statusAncTBL.12
INTEGER
R/W
1 = stream1
2 = stream2
l40statusAncLinkSelect
l40statusAncTBL.13
INTEGER
R/W
1 = a
2 = b
3 = c
4 = d
l40statusAribTBL
l40statusTBL.7
Aggregate
-
-
l40statusAribCcDisp
l40statusAribTBL.1
INTEGER
R/W
1 = text
2 = dump
l40statusAribCcType
l40statusAribTBL.2
INTEGER
R/W
1 = hd
2 = sd
3 = analog
4 = cellular
l40statusAribCcMode
l40statusAribTBL.3
INTEGER
R/W
1 = hex
2 = binary
l40statusAribCcSample
l40statusAribTBL.4
INTEGER
R/W
0 to 258
l40statusAribCcStream
l40statusAribTBL.5
INTEGER
R/W
1 = stream1

Table of Contents