ip radius source-interface
Specify an interface’s IP address as the source IP address for RADIUS connections.
Syntax
ip radius source-interface interface
To delete a source interface, use the no ip radius source-interface
command.
Parameters
interface Enter the following keywords and slot/port or number
information:
For Loopback interfaces, enter the keyword loopback
then a number from zero (0) to 16838.
For the Null interface, enter the keywords null 0.
For a Port Channel interface, enter the keywords port-
channel then a number. The range is from 1 to 128.
For a ten-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port information.
For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE then the slot/port information.
For VLAN interface, enter the keyword vlan then a
number from 1 to 4094.
Defaults Not configured.
Command
Modes
CONFIGURATION
Command
History
Version 8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
radius-server deadtime
Configure a time interval during which non-responsive RADIUS servers to authentication requests are
skipped.
Syntax
radius-server deadtime seconds
To disable this function or return to the default value, use the no radius-server
deadtime command.
Parameters
seconds Enter a number of seconds during which non-responsive
RADIUS servers are skipped. The range is from 0 to
2147483647 seconds. The default is 0 seconds.
Defaults 0 seconds
Security
1175

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell MXL 10GbE and is the answer not in the manual?

Dell MXL 10GbE Specifications

General IconGeneral
Data Transfer Rate10 Gbps per port
Switching Capacity1.28 Tbps
Connectivity TechnologyWired
ModelMXL 10GbE
TypeSwitch
Power SupplyDual hot-swappable power supplies
ManagementCLI, Web-based GUI, SNMP
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Humidity10% to 90% non-condensing
Dimensions17.3 x 17.4 x 1.7 inches (43.9 x 44.2 x 4.3 cm)

Related product manuals