EasyManua.ls Logo

Dell MXL 10GbE - 51 Stacking

Dell MXL 10GbE
1545 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
51
Stacking
For more information about using the MXL 10/40GbE Switch stacking feature, refer to the Stacking MXL
10/40GbE Switches chapter in the Dell Networking OS Configuration Guide.
redundancy disable-auto-reboot
Prevent the MXL 10/40GbE switch stack management unit from rebooting if it fail.
Syntax
redundancy disable-auto-reboot stack-unit [0–5 | members]
To return to the default, use the no redundancy disable-auto-reboot
stack-unit [0–5 | members] command.
Defaults Disabled (the failed switch is automatically rebooted).
Command
Modes
CONFIGURATION
Command
History
Version 8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage
Information
When the command is given as redundancy disable-auto-reboot stack-
unit
, it prevents the MXL 10/ 40GbE switch stack management unit and standby
unit from rebooting if they fail.
When a particular unit number in the range from 0 to 5 is issued as part of the CLI,
it prevents that particular unit from rebooting after failure.
When members are issued as part of the CLI, all the units part of the stack are
prevented from rebooting after failure.
The unit does not reboot until it is manually rebooted.
Related
Commands
show redundancy — displays the current redundancy status.
Stacking
1255

Table of Contents

Related product manuals