Usage
Information
In the fabric-id vlan command, the fabric and VLAN ID numbers must be the
same.
In each FCoE map, the fabric ID, FC-MAP value, and FCoE VLAN parameters must
be unique.
To remove a fabric-VLAN association from an FCoE map, enter the no fabric-id
vlan command.
You must first create a VLAN and then specify the configured VLAN ID in the
fabric-id vlan command. Otherwise, the following error message is displayed.
FTOS(conf-fcoe-f)#fabric-id 10 vlan 10 % Error: Vlan 10 does
not exist
Related
Commands
fcoe-map — creates an FCoE map which contains the parameters used in the
communication between servers and a SAN fabric.
show fcoe-map— displays the Fibre Channel and FCoE configuration parameters in
FCoE maps.
fcf-priority
In an FCoE map, configure the priority used by a server CNA to select an upstream FCoE forwarder (FCF).
M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO module
Syntax
fcf—priority priority
Parameters
priority Enter the priority assigned to the M I/O Aggregator and MXL
10/40GbE Switch with the FC Flex IO module NPIV proxy
gateway, which appears to a downstream server CNA as an
FCF. The range of FCF priority values is from 1 to 255.
Defaults 128
Command
Modes
FCOE MAP
Command
History
Version 9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE
Switch with the FC Flex IO module.
Usage
Information
The FCF priority you assign to an M I/O Aggregator and MXL 10/40GbE Switch with
the FC Flex IO module is used by server CNAs to select an upstream FCF to use for
a fabric login (FLOGI).
To remove a configured FCF priority from an FCoE map, enter the no fcf-
priority
command.
1408
FC Flex IO Modules