3. SPECIFICATIONS
37
Level meter
Displayed Channels 8ch
Dynamic Range SDI-60 dBFS, -90 dBFS, reference level±3 dB
Level Accuracy ±0.3 dB
(-50 to 0 dBFS, 1 kHz, signal source impedance 40 Ω or less)
Frequency Response 30 Hz to 20 kHz ± 0.4 dB (4 dBu, 1 kHz reference, TRUE
PEAK response)
20 Hz to 20 kHz + 0.4 dB, -0.6 dB (4 dBu, 1 kHz reference,
TRUE PEAK response)
Meter Response Model TRUE PEAK, PPM typeⅠ, PPM typeⅡ, VU
Peak Hold Time 0.0 to 5.0 s (in 0.5 s steps), HOLD
Level Setting -40.0 to 0.0 dBFS (standard level, warning level, over level)
Level Numeric Display Displays the levels numerically
Numeric display in red when level-over is detected
Displays a blue “M” when mute is detected (ON/OFF
selectable. The displays changes to a blue ■ when the layout
size is small.)
Displays “U.L” when audio is not detected
Lissajous Display (SER20)
Displayed Channels 2 channels × 1
2 channels × 4
Display Mode X-Y, MATRIX
Correlation Meter Displays the correlation between two channels as a value
from -1 to 1
Channel Assignment
SINGLE LISSAJOU L, R
MULTI LISSAJOU L1, R1 to L4, R4
Surround Display (SER20)
Function Displays a graphical representation of a sound field
Surround Format 5.1 channels
Channel Mapping L, R, C, LFE, Ls, Rs, Lt, Rt
Center Channel Format NORMAL, PHANTOM CENTER
Gain ×1, AUTO

Table of Contents