d-Color MF4003/MF3303
H UTILITY MODE > 6. Administrator
H-11
6. Administrator
6.1Outline
NOTE
▪ The Administrator Settings will be available by entering the administrator password (16 digits) set by the Administrator Settings
or Service Mode. (The administrator password is initially set to “1234567812345678.”)
▪ When [Administrator] -> [Security] -> [Enhanced Security Mode] is enabled, entering the incorrect administrator password three
times will cause access lock. The access lock is released after the lapse of a predetermined period of time (Default setting: 5
min.) after the main power switch is turned OFF and then ON more than 10 seconds later. The access lock can be released by
[Service Mode] -> [Enhanced Security] -> [Administrator unlocking].
6.2Maintenance
Key name Function/Precondition
Meter Count -
ROM Version -
Status Notification Setting -
Total Counter Notification
Setting
-
Date/Time Setting Manual Setting -
Time
Adjustment
Setting
When this setting is enabled, touch [Data Entry] and modify the time.
Daylight Saving Time When this setting is enabled, set the time difference to move up.
• Default setting: 60 min.
• Setting range: 1 to 150
Timer Setting Power Settings Low Power
Mode Setting
The upper limit can be set up to 240 min. only when the switch number
“157” is specified to “02” at HEX assignment by setting [Service Mode] ->
[System 2] -> [Software Switch Setting].
Sleep Mode
Setting
• When [Service Mode] -> [System 1] -> [Sleep ON/OFF Choice Setting]
is set to “Permit”, the setting to turn sleep on and off displays and
becomes selectable.
• The sleep mode will begin in 48 hours even if it sets it to “OFF.”
• The upper limit can be set up to 240 min. only when the switch number
“157” is specified to “02” at HEX assignment by setting [Service Mode] -
> [System 2] -> [Software Switch Setting].
Power
Consumption
in Sleep
Mode
It will not be displayed when image controller is mounted.
Power Save
Settings
-
Enter Power
Save Mode
-
Power Key
Setting
• It will not be displayed when image controller is mounted.
• In ErP auto power OFF mode, this machine cannot receive data or
faxes, and also it cannot scan or print an original.
Power Saving
Fax/Scan
This function is available when the option other than “Copy” is selected in
[Administrator] -> [System Settings] -> [Reset Settings] -> [System auto
reset] -> [Screen to display after startup/Reset].
Awake from
Power Save
Mode by
Touching
Control Panel
-
Weekly Timer
Settings
Use Weekly
Timer
-
Use Power
Save
When “Yes” is selected, using the 10-key pad, input the Power Save Start
Time and Power Save End Time.
Use Overtime
Password
When the setting is enabled, enter the password (eight digits).
Enable
Tracking
Function
-
Network Error Code Display
Setting
-
License Settings Get Request Code -
Install License • By making settings in [Service Mode] -> [Billing Setting], CE can also
activate functions provided by i-Option.