d-Color MF4003/MF3303
I SERVICE MODE > 18. Machine Update Setting
I-125
18. Machine Update Setting
18.1Internet ISW
18.1.1Internet ISW Set
• To use when upgrading the firmware by Internet ISW.
• Each setting such as Server setting will be valid by setting this to “ON”.
NOTE
▪ If [Administrator] -> [Security] -> [Enhanced Security Mode] is set to “ON”, this setting will automatically be set to “OFF” and
cannot be changed.
Setting item Description Setting Default setting
Function setting To set whether or not to enable each setting for Internet ISW. ON
OFF
○
Open Mode Settings This setting is available when Function Setting is set to “Set.”
When “Set” is set, download and update of firmware by Internet ISW is enable by
administrator settings.
Set
Unset
○
18.1.2HTTP Setting
To use when accessing the server using the HTTP protocol.
Setting item Description Setting Default setting
HTTP data acquisition
setting
To set whether or not to enable downloading using the HTTP protocol.
When “ON” is set, set Connection Time-out.
ON
OFF
○
Connection Time-out To set the time for the timeout for accessing the server. 30 to 300 sec. 60 sec.
18.1.3FTP Setting
To use when accessing the server with FTP protocol.
Setting item Description Setting Default setting
FTP data acquisition setting To set whether or not to enable downloading using FTP protocol. ON
○
OFF
Connectio
n Setting
Port Number To set the port number. 1 to 65535 21
Connection
Timeout
To set the timeout time. 1 to 60 (Minute) 1 (Minute)
PASV Mode: To set whether to enable or disable connection by the PASV (passive) mode
(FTP server side will inform the connection port before connecting).
ON
OFF
○
18.1.4Forwarding Access Setting
Setting item Description Setting
User ID To register the user ID for accessing the program server where firmware is to be stored. Alphanumeric characters
and symbols (up to 64
characters)
Password To register the password for accessing the program server where firmware is to be stored. Alphanumeric characters
and symbols (up to 64
characters)
URL To register the user ID for accessing the program server where firmware is to be stored.
• When connecting to http “http:// (Host name or IP address)/ directory name” or “https:// (Host
name or IP address)/directory name”.
• When connecting to ftp “ftp:// (Host name or IP address)/directory name”.
Alphanumeric characters
and symbols (up to 256
characters)
FileName To register the file name of the firmware data to be downloaded. Alphanumeric characters
and symbols (up to 63
characters)
<Procedure>
1. Select a setting item.
2. Enter information using the on-screen keyboard.
18.1.5Download
NOTE
▪ To connect MFP to the Internet via a proxy, the proxy server related settings must be configured in addition to [Forwarding
Access Setting]. The settings of the proxy used in Internet ISW communications is configured in [Administrator] -> [Network] ->
[Machine Update Settings] -> [Internet ISW Settings] -> [FTP Server Setting] or [Administrator] -> [Network] -> [Machine Update
Settings] -> [HTTP Proxy Settings].
▪ If connection to the program server or data download fails, an error code and a message are displayed. Identify the cause of the
problem with the error code and reconfigure the settings following the message. Refer to “ L.6 ERROR CODE FOR THE
INTERNET ISW” for the error codes.
Download/Update
• Access the program server according to the Internet ISW setting, and download the firmware.
• To use when updating the firmware via network.