d-Color MF4003/MF3303
I SERVICE MODE > 10. System 2
I-46
Bit Assignment HEX Assignment Details Default value (Bit/HEX)
00000000 00 “Change Setting” and “Finish” keys become available after
the document has been scanned.
00000000 / 00
10000000 80 Keys unavailable (copy cycle is started)
10.5.5SW No.051
HEX 00 - HEX80
• Settings for the life warning/replace display of the units
Bit Assignment HEX Assignment Details Default value (Bit/HEX)
00000000 00 Normal display 00000000 / 00
00010000 10 Does not show the life warning/replace display of the
imaging unit/Y,M,C.
Does not show the life warning/replace display of the drum
unit/K.
00100000 20 Does not show the life warning/replace display of the
developing unit.
01000000 40 Does not show the life warning/replace display of the
transfer belt unit.
10000000 80 Does not show the life warning/replace display of the fusing
unit.
Reference
• [Service Mode] -> [Counter] -> [Life]
10.5.6SW No.069
• When printing using the manual bypass tray in a custom size, allows for printing only with a printer driver settings.
Bit Assignment HEX Assignment Details Default value (Bit/HEX)
00000000 00 After setting a paper in the manual bypass tray, touch
[complete] key to start printing.
00000001 / 01
00000001 01 Start printing with the paper settings specified by the printer
driver as the manual bypass tray paper settings without
giving a warning.
10.5.7SW No.070
• Setting for alarm sound and screen display for communication errors occurring due to CSRC causes.
Bit Assignment HEX Assignment Details Default value (Bit/HEX)
00000000 00 Communication error sound/screen display enabled. 00000000 / 00
00010000 10 Communication error sound/screen display disabled.
10.5.8SW No.072
• Import/export function of the address book through the USB memory
Bit Assignment HEX Assignment Details Default value (Bit/HEX)
00000000 00 Import/export function is disabled. 00000000 / 00
00000100 04 Import/export function is enabled.
Reference
• [Administrator] -> [Maintenance] -> [External Memory Backup] - [Import]
• [Administrator] -> [Maintenance] -> [External Memory Backup] - [Export]
10.5.9SW No.121
• Operation when an original multi-feed trouble is detected during using the ADF
Bit Assignment HEX Assignment Details Default value (Bit/HEX)
00000000 00 Apply Problem Unit Isolation 00000000 / 00
00000100 04 Not to apply Problem Unit Isolation
10.5.10SW No.124
• Function to restrict the file type of TX Fax
Bit Assignment HEX Assignment Details Default value (Bit/HEX)
00000000 00 Restrict the file type. 00000000 / 00
00000001 01 Do not restrict the file type.
Reference
• [Administrator] -> [Fax Settings] -> [Function Setting] -> [RX Data Operation Settings] -> [Forward TX Setting]