J BILLING SETTING/ENHANCED SECURITY/DEBUG SETTINGS > 1. BILLING
SETTING
J-5
▪ Although [Use Card Reader Settings] is also selectable at [Administrator] -> [User Auth/Account Track] -> [Authentication
Device Settings] -> [Card] -> [IC Card type], "FeliCa" is dedicated for the card reader (OMNIKEY5427CK) settings.
▪ Make card reader (OMNIKEY5427CK) settings with the tool that is exclusively used for PC settings and downloaded from
the HID web page.
1.5Coverage Rate Clear
To clear the coverage rate.
Setting value Contents Default setting
Set Select [Set] and [END] key will clear the coverage rate.
Unset Not cleared
○
1.6License Management
1.6.1Activation
• To activate i-Option functions.
• The functions can be activated by selecting the desired function and enter the appropriate license code and function code.
• Administrators also can carry out the procedure No.14 or later step to activate i-Option functions through Administrator Settings.
NOTE
▪ You need to access License Management System (LMS) to implement each function setting.
▪ Before accessing the LMS, CE are required to register the E-mail address and the password in the LMS. To register, click [CE
Initial Registration] that is located in the upper right of CE Login screen.
<Procedure>
1. Prepare “token certification.”
2. Access the following URL using the PC connected to the Internet.
https://lms.olivetti.com/license/OLI/support.aspx
3. Click [CE Login].
4. Enter [E-Mail Address] and [Password], and click [Login].
5. Click [Generate License Code].