H UTILITY MODE > 7. Expert Adjustment
H-28
7. Expert Adjustment
NOTE
It will not be displayed when [Service Mode] -> [Billing Setting] -> [Management Function Choice] shows that the “Vendor 2” is
mounted. (It will be displayed when the Key Counter is mounted or [Service Mode] -> [System 2] -> [Software Switch Setting]
shows that switch No.33 is set to [00000001] at Bit assignment/[01] at HEX assignment.)
Key name Function/Precondition
AE Level Adjustment -
Printer Adjustment Leading Edge Adjustment This menu is unavailable when the key counter is not inserted while “Key Counter
Only” is set by [Service Mode] -> [Billing Setting] -> [Management Function Choice].
Centering
Leading Edge Adjustment
(Duplex Side 2)
Centering (Duplex 2nd
Side)
Erase Leading Edge It will be displayed when [Service Mode] -> [Enhanced Security] -> [Administrator
Feature Level] is set to “Level 2.”
The adjusted values from [Erase Leading Edge] are also updated to the service
mode as the “Lead Edge Erase Adjustment” function in service mode is opened
to administrators.
The adjusted values from [Vertical Adjustment] are also updated to the service
mode as the “Paper Feed Direction Adj.” function in service mode is opened to
administrators.
Vertical Adjustment
Media Adjustment This function is provided to open “Transfer Voltage Fine Adj” of Service Mode up to
administrator and the fine-adjusted value is reflected in the Service Mode setting.
Image Stabilization -
Paper Separation
Adjustment
-
Color Registration Adjust This menu is unavailable when the key counter is not inserted while “Key Counter Only” is set by [Service Mode] -
> [Billing Setting] -> [Management Function Choice].
Gradation Adjustment This menu is unavailable when the key counter is not inserted while “Key Counter Only” is set by [Service
Mode] -> [Billing Setting] -> [Management Function Choice].
Before executing Gradation adjust, be sure to perform Image Stabilization.
Scanner Area It will be displayed when [Service Mode] -> [Enhanced Security] -> [Administrator Feature Level] is set to
“Level 2.”
This menu is unavailable when the key counter is not inserted while “Key Counter Only” is set by [Service
Mode] -> [Billing Setting] -> [Management Function Choice].
The adjusted values from [Scanner Area] are also updated to the service mode as the “Scan Area” function in
service mode is opened to administrators.
ADF Adjustment Centering It will be displayed when [Service Mode] -> [Enhanced Security] -> [Administrator
Feature Level] is set to “Level 2.”
Original Stop Position
Centering Auto Adjustment It will be displayed when [Service Mode] -> [Enhanced Security] -> [Administrator
Feature Level] is set to “Level 2.”
When the adjustment result is [Unable], confirm the orientation of the original
document and manually adjust the [Original Stop Position].
Auto Adj. of Stop Position
User Paper Settings It will be displayed when [Service Mode] -> [Enhanced Security] -> [Administrator Feature Level] is set to
“Level 2.”
The feature available from [Service Mode] -> [System 2] -> [User Paper Settings] is extended to
Administrator. However, the fusing temperature setting is not possible in Administrator Settings.
Erase Adjustment -
PS Designer Settings -
Main Scanning Direction
Zoom
-
Trouble isolation It will be displayed when the finisher is mounted.
Service Manual
Y119930-3

Table of Contents

Other manuals for Olivetti d-Color MF4003

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Olivetti d-Color MF4003 and is the answer not in the manual?

Olivetti d-Color MF4003 Specifications

General IconGeneral
BrandOlivetti
Modeld-Color MF4003
CategoryCopier
LanguageEnglish

Related product manuals