EasyManuals Logo

Olivetti d-Color MF4003 User Manual

Olivetti d-Color MF4003
688 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #493 background imageLoading...
Page #493 background image
d-Color MF4003/MF3303
L TROUBLESHOOTING > 8. CS Remote Analysis ERROR CODE
L-95
Error code Contents Solution
• Session ID inconsistent
8.2.43###
Error code Contents Solution
3002 http request result problem
• Unopened client ID was specified
Check the http server system settings.
• Authentication setting for address of the
destination where the server is connected
• Location indicated for a folder
• Connection ID
• Password
3003 http request result problem
• Receive time out occurred
3004 http request result problem
• Receive error occurred. Or wrong request URL was specified.
3005 http request result problem
• Content-Length or receive size exceeded the specified max.
transfer size. Message body size was too large.
3006 http request result problem
• Due to reset, process was stopped. Or message body size
exceeded the specified max. transfer size.
3007 http request result problem
• Internal error occurred. Or due to internal reset, process was
stopped.
3008 http request result problem
• Connection to WebDAV server failed.
3009 http request result problem
• Error occurred during transmission to the WebDAV server.
3010 http request result problem
• Time out occurred during transmission to the WebDAV server.
3011 http request result problem
• Connection to the proxy server failed.
3012 http request result problem
• The proxy server refused CONNECT request.
3013 http request result problem
• The proxy server was set to enabled, but the proxy server host
was not set.
3014 http request result problem
• Proxy server authentication failed.
3015 http request result problem
• Other errors were sent from the proxy server.
3016 http request result problem
• Internal error occurred.
3017 http request result problem
• As the device application specified MIO_REQBODY_ERROR,
process was stopped.
8.2.54###
Error code Contents How to correct
4103 After the main power switch is switched ON, HTTP communication is
attempted under the condition where HTTP communication is not
ready.
Wait for a while and try transmitting again.
4106 When data is uploaded from main body to the web server, the network
connection is not enabled and main body cannot start communication.
Wait for a while and try transmitting again.
41FA Control error
• MIO response timed out.
Turn the main power switch OFF and then ON.
8.2.65###
Error code Contents Solution
5### MIO detects error at file sending. Check the http server environment.
8.2.76###
Error code Contents Solution
6### MIO detects error during a sending sequence. Check the http server environment.
8.2.87###
Error code Contents Solution
7000 Acquisition of the certificate used in product authentication from a USB
device or PSWC failed.
Acquire a new certificate (within 6 days after the
issue).
Y119930-3
Service Manual

Table of Contents

Other manuals for Olivetti d-Color MF4003

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Olivetti d-Color MF4003 and is the answer not in the manual?

Olivetti d-Color MF4003 Specifications

General IconGeneral
BrandOlivetti
Modeld-Color MF4003
CategoryCopier
LanguageEnglish

Related product manuals