d-Color MF4003/MF3303
I SERVICE MODE > 18. Machine Update Setting
I-129
NOTE
▪ It will not be displayed when [Service Mode] -> [Network Settings] -> [Remote Service Setting] -> [Function Settings] -> [Enable
Settings] is set to “ON.” [Machine Auto Update setting] in “Administrator” is not applicable.
▪ When the SMB protocol used, the MFP uses static IP addresses.
Server 1 Settings
Setting item Description Setting Default
setting
Auto Update To set whether or not to use the auto update setting.
• When [ON] is selected, configure the settings for Acquisition
protocol.
ON
OFF
○
Server Name To set an arbitrary server name to identify the connection destination. Alphanumeric
characters (up to 20
characters)
Server1
Download Protocol To set the protocol for acquiring an update data.
• If the MFP relay server is used as a server on the data providing
side, select [HTTP].
SMB
○
HTTP
SMB Setting Host Name Set the host name for the SMB server. Alphanumeric
characters and
symbols (up to 253
characters)
-
File Path Set the file path used for SMB server communication.
• Specify the folder in which C_UpdateList.ini is stored.
Up to 255 characters -
User Name Set the user name used to access the SMB server. Up to 64 characters -
Password Set the password used to access the SMB server. Alphanumeric
characters and
symbols (up to 64
characters)
-
Number of retries Set the number of times to retry when failed to obtain. 0 to 10 count 3 times
HTTP
Setting
URL Set the address of the http server.
• Specify the folder in which C_UpdateList.ini is stored.
Alphanumeric
characters and
symbols (up to 253
characters)
-
User Name Set the user name used to access the relay server by http protocol. Up to 64 characters -
Password Set a password used to access the http server. Alphanumeric
characters and
symbols (up to 64
characters)
-
Proxy To set whether or not to use the proxy server.
• If [ON] is selected, set the proxy with [Administrator] -> [Network] ->
[Machine Update Settings] -> [HTTP Proxy Settings].
ON
OFF
○
Connection Time-
out
To set the time for the timeout for accessing the server. 30 - 300 60 Sec.
Server 2 settings
Setting item Description Setting Default
setting
Auto Update To set whether or not to use the auto update setting.
• When [ON] is selected, configure the settings for Acquisition
protocol.
ON
OFF
○
Server Name To set an arbitrary server name to identify the connection destination. Alphanumeric
characters (up to 20
characters)
Server2
HTTP
Setting
URL To set the address of the http server.
• Specify the folder in which C_UpdateList.ini is stored.
Alphanumeric
characters and
symbols (up to 253
characters)
-
User Name Set the user name used to access the relay server by http protocol. Up to 64 characters -
Password Set a password used to access the http server. Alphanumeric
characters and
symbols (up to 64
characters)
-
Proxy To set whether or not to use the proxy server.
• If [ON] is selected, set the proxy with [Administrator] -> [Network] ->
[Machine Update Settings] -> [HTTP Proxy Settings].
ON
OFF
○
Connection Time-
out
To set the time for the timeout for accessing the server. 30 - 300 60 Sec.
Common Settings
• Configure the common settings for [Server 1 settings] and [Server 2 settings].