d-Color MF4003/MF3303
J BILLING SETTING/ENHANCED SECURITY/DEBUG SETTINGS > 2. ENHANCED
SECURITY
J-24
NOTE
â–ª To reflect the adjustment value after change, make sure to exit from the Service Mode.
â–ª The adjustment value is not reflected when turning off the power without exiting from the Service Mode.
(14)Choice 1 of extending PU life
To change the imaging unit life threshold.
Switch No.33 Contents Default
OFF To use the default threshold.
â—‹
ON To use the threshold 1.25 times the normal one.
(15)Choice 2 of extending PU life
To change the imaging unit life threshold.
Switch No.34 Contents Default
OFF To use the default threshold.
â—‹
ON To use the threshold 1.5 times the normal one.
(16)Choice of improving fusibility strength
• Choice to raise fusing temperature to secure fusibility for the image erasing problem with eraser test
Switch No. 35 Contents Default
OFF -
â—‹
ON Raise the fusing temperature.
(17)Choice of silent mode
• Switches the drive for the polygon motor, fusing, and fan during standby.
Switch No.37 Contents Default
OFF Normal mode
â—‹
ON Silent mode Level (highest-speed rotation before printing/after printing is not energized)
(18)Choice of disabling engine log via CTL
• Choice to disable an engine log via CTL
Switch No.39 Contents Default
OFF To enable an engine log via CNT.
â—‹
ON To disable an engine log via CNT. (Terminal output)
NOTE
â–ª To reflect the adjustment value after change, make sure to exit from the Service Mode.
â–ª The adjustment value is not reflected when turning off the power without exiting from the Service Mode.
(19)Choice of increasing registration stabilization frequency
• Choice of increasing registration stabilization frequency by PH temperature change
Switch No.42 Contents Default
OFF Disable
â—‹
ON Enable
(20)Choice of HH memory upper limit voltage
• Release protection against upper limit voltage of 1st transfer
Switch No.43 Contents Default
OFF With protection against upper limit voltage of 1st transfer
â—‹
ON No protection against upper limit voltage of 1st transfer
(21)Choice of UFP behavior mode
• Choice to conduct a control to restrict the occurrence of UFP
Switch No.46 Contents Default
OFF Not to conduct a control to restrict the occurrence of UFP.
â—‹ (Except for
Europe)
ON Not to conduct a control to restrict the occurrence of UFP.
â—‹ (Europe only)
NOTE
â–ª To reflect the adjustment value after change, make sure to exit from the Service Mode.
â–ª The adjustment value is not reflected when turning off the power without exiting from the Service Mode.