Page #239 background imageLoading...
Page #239 background image
d-Color MF4003/MF3303
I SERVICE MODE > 8. CS Remote
I-23
Initial Transmission
Touching the Initial Transmission key will sent the information to the CS Remote Care center to register the machine.
(b)Date & Time Setting
To set the data and time-of-day.
<Procedure>
1. Touch [Date & Time Setting].
2. Enter the date (month, day and year), time-of-day, and the time zone from the 10-key pad.
3. Touch [SET] to start the clock.
(c)RAM Clear
To clear the following data at the center.
Service ID, Basic setting, Date & time setting (time zone), Software SW setting, AT command
To be used for setting CS Remote Care.
To be used for reset the every data of the center to default.
NOTE
If RAM clear is selected during transmission, RAM clear processing will be implemented at the time the transmission is
completed regardless of whether it is done properly or not.
Setting value Default setting
Set
Unset
(d)Communication Log Print
To print out the communication log.
It will be displayed when “Fax” is selected in System Setting.
<Procedure>
1. Touch [Communication Log Print].
2. Load a paper tray with A4S/A4 or 81/2 x 11S/81/2 x 11 paper.
3. Select [1-Sided] or [2-Sided].
4. Press Start key to print out the communication log.
(e)Software Switch Setting
To change the CS Remote Care settings.
NOTE
Software SW bits data are written into the MFP storage every time a change is made. In case you changed bit data by
accident, be sure to restore the previous state.
Do not change any bit not described on this table.
<Procedure>
1. Touch [Software Switch Setting].
2. Touch [Switch No.], and input the software switch number (two digits) using the 10-key pad.
3. Touch [Bit Assignment], and select software switch bit number using the arrow keys, and input 0 or 1 using the 10-key pad. (For setting
by hexadecimal numbers, touch [HEX Assignment] key, and input using the 10-key pad or A to F keys.)
Refer to “ I.8.2 Software SW setting for Remote Care” for the setting items.
4. Touch [Fix].
(f)Response Time Out
Set the timeout until the response arrives from the center during e-mail communication.
This setting is available only when “E-Mail1” or “E-Mail2” is selected in [System Setting].
Setting range Default setting
10 to 1440 60 minutes
(g)AT Command
To set the command to be issued at the time of modem initialization.
Enter the command and touch [SET] to register.
This setting is available only when [Modem] is selected in [System Setting].
(h)Notification Setting
To make the settings of notification to the center that is performed under unilateral communication via http.
This setting is available only when [http2] is selected in [System Setting].
Schedule
Set the schedule of notification to the center.
Up to three different notification schedules can be registered.
<Procedure>
1. Select the key of the registration number, and then touch [Enable].
2. Select the notification cycle from [Day], [Week], or [Month].
When selecting [Day] for the notification cycle, set the Day Frequency.
When selecting [Week] for the notification cycle, set the Week Frequency and day of the week.
When selecting [Month], set the Month Frequency and the date of the month.
3. Touch [SET] to register the schedule.
Center Notifi. Item
To set whether or not to notify the Center.
Y119930-3
Service Manual

Table of Contents

Other manuals for Olivetti d-Color MF4003

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Olivetti d-Color MF4003 and is the answer not in the manual?

Olivetti d-Color MF4003 Specifications

General IconGeneral
BrandOlivetti
Modeld-Color MF4003
CategoryCopier
LanguageEnglish

Related product manuals