d-Color MF4003/MF3303
I SERVICE MODE > 16. FAX
I-112
Items Address Data Default
Line 1 Line 2 Line 3 Line 4 Bit Contents Setting Data
01011110
(EU)
20 pps pulse dial
make time
000E00E6 000E01F6 000E0306 000E0416 7-0 20 pps pulse dial make time 7 (JP)
9 (US/EU)
00000111
(JP)
00001001
(US/EU)
20 pps pulse dial
break time
000E00E7 000E01F7 000E0307 000E0417 7-0 20 pps pulse dial break time 16 (JP)
14 (US/EU)
00010000
(JP)
00001110
(US/EU)
20 pps pulse dial
inter-digit pause
000E00E8 000E01F8 000E0308 000E0418 7-0 20 pps pulse dial inter digit
pause (unit: 10 ms)
890 ms (JP)
640 ms (US)
920 ms (EU)
01011001
(JP)
01000000
(US)
01011100
(EU)
PB signal
transmission level
000E00E9 000E01F9 000E0309 000E0419 7-0 PB signal transmission level
(unit: 1 dBm)
10 dBm (JP/US)
6 dBm (EU)
00001010
(JP/US)
00000110
(EU)
PB signal level
difference (H-L)
000E00EA 000E01FA 000E030A 000E041A 7-0 PB signal level difference (H-
L) (unit: 0.5 dBm)
2 dBm 00000100
DC-LOOP
integration time at
CML OFF
000E00EB 000E01FB 000E030B 000E041B 7-0 DC-LOOP integration time at
CML relay OFF (unit: 5 ms)
(Lower limit 20 ms)
400 ms 01010000
DC-LOOP
integration time at
CML ON
000E00EC 000E01FC 000E030C 000E041C 7-0 DC-LOOP integration time at
CML relay ON (unit: 5 ms)
(Lower limit 20 ms)
80 ms 00010000
Pause time 000E00ED 000E01FD 000E030D 000E041D 7-3 - - 00000001
2-0 Pause time (unit: sec.) 1 sec.
DC-LOOP check
mode
000E00EE 000E01FE 000E030E 000E041E 7 DC-LOOP check
0: No
1: Always
No 00000000
6-1 - -
0 T81 line disconnection check
(T80 if line disconnected)
0: Yes
1: No
Yes
DC-LOOP waiting
time
000E00EF 000E01FF 000E030F 000E041F 7-0 DC-LOOP waiting time (unit:
100 ms)
0 ms 00000000
DC-LOOP
instantaneous
break allowable
time (ph.A)
000E00F0 000E0200 000E0310 000E0420 7-0 DC-LOOP instantaneous
break allowable time (unit: 10
ms)
(at the time of calling, CML
ON to end of dialing)
0 ms 00000000
DC-LOOP
instantaneous
break allowable
time (ph.B)
000E00F1 000E0201 000E0311 000E0421 7-0 DC-LOOP instantaneous
break allowable time (unit: 10
ms)
(after completion of dialing
and after CML ON at the time
of reception)
0 ms 00000000
Dial mode RING
DET mode
000E00F2 000E0202 000E0312 000E0422 7 Wrong dial determination
function
0: Disable
1: Enable
Disable 00010010
(JP)
00010000
(US/EU)
6 - -
5-4 RING detection mode
01: No. of times
10: Time
No. of times
3-2 Pulse format
00: General
01: SW
10: NO
General
1-0 Dialing method
00: PB
01: 10 pps
10: 20 pps
11: 16 pps
20 pps (JP)
PB (US/EU)