P.A.11
Date Code 20151029 Protection Manual SEL-411L Relay
Firmware and Manual Versions
Manual
Section 6
➤ Added PMLEGCY setting to Table 6.1: PMU Settings in the relay for C37.118 Protocol in Global Settings.
➤ Added text to describe the synchrophasor aliasing feature.
Section 7
➤ Added text about Segregating Ethernet Ports.
20150126
Preface
➤ Updated Safety Information.
20141224
General
➤ Removed references to future release.
Protection Manual
Section 3
➤ Added notes to clarify incoming and outgoing VLAN ID settings and VLAN unaware network behavior.
➤ Updated Table 3.19: User-Programmable Communications Bits Settings and Table 3.20: 87L User-
Programmable Communications Bits (Ethernet) Relay Word Bits to show the additional communications bits.
➤ Updated Table 3.40: Current Line Differential Elements Operating Times—Serial Communication.
➤ Added Table 3.41: Current Line Differential Operating Times—Ethernet Communication.
➤ Added Figure 3.55: Phase Elements Operating Times—Ethernet Communication.
➤ Added Figure 3.56: Negative-Sequence Elements Operating Times—Ethernet Communication.
➤ Added Figure 3.57: Zero-Sequence Elements Operating Times—Ethernet Communication.
➤ Changed LLT setting in Table 3.61: Fault Location Settings for 4-Terminal Line With Two TAP Points.
➤ Changed the 87LVLAN setting in Table 3.142: Ethernet VLAN Settings.
➤ Added SEL Recommended Network Topologies.
Section 5
➤ Added Table 5.24: 87L Communication Bits Transmit Equations.
➤ Added 87ETHJT setting to Table 5.45: 87L Port Settings.
➤ Added Table 5.47: 87L Communications Bits Debounce Time Delay—Serial Communication.
➤ Added Table 5.48: 87L Communications Bits Debounce Time Delay—Ethernet Communication.
Appendix A
➤ Updated for firmware version R116.
20140912
Protection Manual
Section 3
➤ Updated Figure 3.183: Blocking Logic for the 87L Function.
➤ Updated Table 3.105: U.S. Time-Overcurrent Equations.
➤ Updated Table 3.106: IEC Time-Overcurrent Equations.
Appendix A
➤ Updated for firmware version R115.
20140429
Protection Manual
Section 1
➤ Added Power Supply burdens <90 VA to Specifications.
➤ Added AC Thresholds <5 ma at nominal voltage and <8 ma for 110 V option to Specifications.
➤ Added Damped Oscillatory Magnetic field to Specifications.
➤ Removed Serial IRIG isolation specifications.
Section 3
➤ Added note for Matrix “12” in Table 3.31: Transformer Winding Compensation Matrices.
➤ Updated Table 3.59: Fault Location Settings for 2-, 3-, and 4-terminal lines with one tap point.
➤ Added note for setting TRCOMM in DCB schemes.
➤ Updated Table 3.90: Quadrilateral Ground Distance Element Settings.
➤ Updated Figure 3.183: Blocking Logic for the 87L Function.
➤ Updated the 87CTCWL settings for local and remote terminals from 12 and 11 to 1 and 0 under Three-Termi-
nal 345 kV Line Differential Example.
Table A.5 Manual Revision History (Sheet 3 of 6)
Revision Date Summary of Revisions