Date Code 20151029 Protection Manual SEL-411L Relay
Firmware and Manual Versions
Manual
Section 5
Increased maximum number of concurrent IEC 61850 MMS sessions from six to seven.
Increased the number of simultaneous IEC 61850 MMS client sessions from six to seven.
Increased virtual bits and remote analogs from 128 to 256.
Increased number of report control blocks from 12 to 14.
Increased number of buffered and unbuffered reports from six to seven.
Added Parallel Redundancy Protocol (PRP).
Updated Figure 5.1: Relay Predefined Reports and Figure 5.2: Relay Datasets.
Updated Table 5.4: Buffered Report Control Block Client Access, Table 5.5: Unbuffered Report Control Block
Client Access, Table 5.7: Logical Device: PRO (Protection), and Table 5.9: Logical Device: MET (Metering).
20130821
Protection Manual
Section 1
Added UL, cUL certification to Specifications.
20130621
Protection Manual
Section 3
Added Polarizing Quantity for Distance Element Calculations.
Updated Figure 3.105: Logic Diagram of the Three-Phase Fault Detector.
Appendix A
Updated for firmware version R110.
Added information in Table A.1 (R108 release) explaining changes to the time constants of the memory voltage.
20130401
Protection Manual
Section 1
Added 6U Chassis option in Models and Options.
Updated Specifications.
Section 2
Added 6U Chassis option in Shared Configuration Attributes, Plug-In Boards, Jumpers, and Connection.
Updated steps for Installing Optional I/O Interface Boards in Plug-In Boards.
Updated Figure 2.22: Chassis Dimensions.
Section 3
Updated Figure 3.69: Relay Exchanging TW Peak Information Via 87L Communications Channel.
Added note to Quadrilateral Phase Nonhomogeneous Setting (TANGP).
Updated Figure 3.139: Over/Undervoltage Logic.
Updated Figure 3.175: C37.94, 850/1300 nm Typical Connection.
Updated Direct Fiber-Optic Interfaces.
Removed SALARM from Figure 3.181: Blocking Logic for the 87L Function.
Updated Protection Application Examples.
Added note to describe the calculation of the positive sequence voltage under a Single Pole Open (SPO) condi-
tion in Loss-of-Potential Logic.
Added note to describe the calculation of the Quadrilateral Phase resistive reach in Quadrilateral Phase Dis-
tance Elements.
Updated Table 3.131: EIA-422 Configuration Settings and Cables.
Added note to time-based synchronized settings that the setting requires a C37.118 compliant clock in 87L
Communication and Timing.
Appendix A
Updated for firmware version R109.
Added Table A.2: Firmware Compatibility.
Appendix B
Added note to Overview about matching firmware in SEL-411L Relays.
Added footnote to Table B.1: Firmware Upgrade Files.
Updated Troubleshooting.
Table A.5 Manual Revision History (Sheet 5 of 6)
Revision Date Summary of Revisions

Table of Contents

Related product manuals