1-10
display ipv6 nd detection
Syntax
display ipv6 nd detection
View
Any view
Parameters
None
Description
Use the display ipv6 nd detection command to display ND detection configuration.
Refer to the ipv6 nd detection enable command and ipv6 nd detection trust command for related
configuration.
Among S3100 series switches, only S3100-EI series switches support the two commands.
Examples
# Display ND detection configuration.
<Sysname> display ipv6 nd detection
ND detection is enabled in the following VLANs:
2, 10
ND detection trust is configured on the following interfaces:
Interface Trusted
Eth1/0/1 yes
Eth1/0/3 yes
Table 1-6 display ipv6 nd detection command output description
Field Description
ND detection is enabled in the following VLANs: The VLAN enabling the ND detection
ND detection trust is configured on the following
interfaces
Lists of ND trust ports
display ipv6 nd detection statistics
Syntax
display ipv6 nd detection statistics [ interface interface-type interface-number ]
View
Any view
Parameters
interface interface-type interface-number: Displays the statistics of the specified interface.
interface-type interface-number: Specifies the interface type and number

Table of Contents

Other manuals for H3C S3100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3100 Series and is the answer not in the manual?

H3C S3100 Series Specifications

General IconGeneral
BrandH3C
ModelS3100 Series
CategorySwitch
LanguageEnglish

Related product manuals