1-12
oam errored-frame-period threshold
Syntax
oam errored-frame-period threshold threshold-value
undo oam errored-frame-period threshold
View
System view
Default Level
2: System level
Parameters
threshold-value: Errored frame period event triggering threshold, ranging from 0 to 4294967295.
Description
Use the oam errored-frame-period threshold command to set the errored frame period event
triggering threshold.
Use the undo oam errored-frame-period threshold command to restore the default.
By default, the errored frame period event triggering threshold is 1.
Related commands: oam errored-frame-period period, display oam link-event, display oam
configuration.
Examples
# Set the errored frame period event triggering threshold to 100.
<Sysname> system-view
[Sysname] oam errored-frame-period threshold 100
oam errored-frame-seconds period
Syntax
oam errored-frame-seconds period period-value
undo oam errored-frame-seconds period
View
System view
Default Level
2: System level
Parameters
period-value: Errored frame seconds detection interval, ranging from 10 to 900 (in seconds).
Description
Use the oam errored-frame-seconds period command to set the errored frame seconds detection
interval.