3-4
Table 3-3 Description on the fields of the display device command
Field Description
SlotNo Serial number of the slot
SubSNo Serial number of the sub slot
PortNum Number of ports
PCBVer Version number of the PCB card
FPGAVer Version number of the FPGA encapsulation
CPLDVer Logical version number of the hardware CPLD
BootRomVer Version number of the Boot ROM
AddrLM MAC address learning mode
Type Card type
State Running state
display environment
Syntax
display environment
View
Any view
Parameter
None
Description
Use the display environment command to view the environment temperature of the switch.
Note that only PoE-enabled S3100 series Ethernet switches support this command currently.
Example
# Display the environment temperature of the switch.
<Sysname> display environment
Unit 1:
Slot 0: Normal Temperature
Subslot 1: Normal Temperature
Subslot 2: Normal Temperature
Power 1: Normal Temperature
Power 2: Normal Temperature
display fan
Syntax
display fan [ unit unit-id [ fan-id ] ]
View
Any view