1-31
ipv6 nd nud reachable-time
Syntax
ipv6 nd nud reachable-time value
undo ipv6 nd nud reachable-time
View
VLAN interface view
Parameters
value: Neighbor reachable time in milliseconds, in the range of 1 to 3,600,000.
Description
Use the ipv6 nd nud reachable-time command to configure the neighbor reachable time on an
interface.
Use the undo ipv6 nd nud reachable-time command to restore the default.
By default, the neighbor reachable time on the local interface is 30,000 milliseconds.
Related commands: display ipv6 interface.
Examples
# Set the neighbor reachable time on the VLAN-interface 1 to 10,000 milliseconds.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] interface Vlan-interface 1
[Sysname-Vlan-interface1] ipv6 nd nud reachable-time 10000
ipv6 nd detection enable
Syntax
ipv6 nd detection enable
undo ipv6 nd detection enable
View
VLAN view
Parameters
None
Description
Use the ipv6 nd detection enable command to enable the ND detection, namely check the user
legality of ND packets.
Use the undo ipv6 nd detection enable command to disable the ND detection.
By default, the ND detection is disabled.
Among S3100 series switches, only S3100-EI series switches support the two commands.

Table of Contents

Other manuals for H3C S3100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3100 Series and is the answer not in the manual?

H3C S3100 Series Specifications

General IconGeneral
BrandH3C
ModelS3100 Series
CategorySwitch
LanguageEnglish

Related product manuals