1-3
Field Description
PRIORITY
PoE priority of the port:
z critical: Highest
z high: High
z low: Low
STATUS
PoE status on the port:
z user command set port to off: PoE to the port is turned off by the user
z Standard PD was detected: A standard PD is detected
z Legacy PD was detected: A non-standard PD is detected
z PD detection is in process: PDs are being detected
z If the poe enable command is configured on a port, and the port is not connected to
a standard PD (for example, a PC), “ non-standard PD connected” will be
displayed.
display poe interface power
Syntax
display poe interface power [ interface-type interface-number ]
View
Any view
Parameter
interface-type interface-number: Port type and port number.
Description
Use the display poe interface power command to view the power information of a specific port of the
switch. If the interface-type interface-number argument is not specified, the command displays the
power information of all ports of the switch.
Example
# Display the power information of Ethernet 1/0/10.
<Sysname> display poe interface power Ethernet1/0/10
Port power :12400 mW
# Display the power information of all ports.
<Sysname> display poe interface power
PORT INDEX POWER (mW) PORT INDEX POWER (mW)
Ethernet1/0/1 0 Ethernet1/0/2 0
Ethernet1/0/3 0 Ethernet1/0/4 0
Ethernet1/0/5 0 Ethernet1/0/6 0
Ethernet1/0/7 0 Ethernet1/0/8 0
Ethernet1/0/9 0 Ethernet1/0/10 12400
……
<Omitted>
display poe powersupply
Syntax
display poe powersupply