1-3
garp timer
Syntax
garp timer { hold | join | leave } timer-value
undo garp timer { hold | join | leave }
View
Ethernet port view
Parameters
hold: Sets the GARP Hold timer.
join: Sets the GARP Join timer.
leave: Sets the GARP Leave timer.
timer-value: Timeout time (in centiseconds) of the GARP timer (Hold, Join or Leave) to be set.
Description
Use the garp timer command to set a GARP timer (that is, the Hold timer, the Join timer, or the Leaver
timer) for an Ethernet port.
Use the undo garp timer command to restore the default setting of a GARP timer.
By default, the Hold, Join, and Leave timers are set to 10, 20, and 60 centiseconds.
Note that:
z The setting of each timer must be a multiple of 5 (in centiseconds).
z The timeout ranges of the timers vary depending on the timeout values you set for other timers. If
you want to set the timeout time of a timer to a value out of the current range, you can set the
timeout time of the associated timer to another value to change the timeout range of this timer.
The following table describes the relations between the timers:
Table 1-2 Relations between the timers
Timer Lower threshold Upper threshold
Hold 10 centiseconds
This upper threshold is less than or equal to
one-half of the timeout time of the Join timer.
You can change the threshold by changing
the timeout time of the Join timer.
Join
This lower threshold is greater than or
equal to twice the timeout time of the
Hold timer. You can change the
threshold by changing the timeout time
of the Hold timer.
This upper threshold is less than one-half of
the timeout time of the Leave timer. You can
change the threshold by changing the timeout
time of the Leave timer.
Leave
This lower threshold is greater than
twice the timeout time of the Join timer.
You can change the threshold by
changing the timeout time of the Join
timer.
This upper threshold is less than the timeout
time of the LeaveAll timer. You can change
the threshold by changing the timeout time of
the LeaveAll timer.
LeaveAll
This lower threshold is greater than the
timeout time of the Leave timer. You can
change threshold by changing the
timeout time of the Leave timer.
32,765 centiseconds

Table of Contents

Other manuals for H3C S3100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3100 Series and is the answer not in the manual?

H3C S3100 Series Specifications

General IconGeneral
BrandH3C
ModelS3100 Series
CategorySwitch
LanguageEnglish

Related product manuals