1-1
1 HWPing Commands
HWPing Client Commands
adv-factor
Syntax
adv-factor adv-number
undo adv-factor
View
HWPing test group view
Parameters
adv-number: Advantage factor, used to count Mos and ICPIF value in a jitter voice test. It is in the range
0 to 20 and defaults to 0.
Description
Use the adv-factor command to configure the advantage factor which is used to count Mos and ICPIF
value in a jitter voice test.
Use the undo adv-factor command to restore the default.
This command applies only to jitter voice test.
Examples
# Configure the advantage factor for a jitter voice test as 10.
<Sysname> system-view
System View: return to User View with Ctrl+Z
[Sysname] hwping administrator jitter
[Sysname-hwping-administrator-jitter] test-type jitter codec g711a
[Sysname-hwping-administrator-jitter] adv-factor 10
count
Syntax
count times
undo count
View
HWPing test group view
Parameters
times: Number of probes in each HWPing test. The times argument ranges from 1 to 15.