2-7
Examples
# Set the MLD last listener query interval to 3 seconds globally.
<Sysname> system-view
[Sysname] mld-snooping
[Sysname-mld-snooping] last-listener-query-interval 3
max-response-time (MLD-Snooping view)
Syntax
max-response-time interval
undo max-response-time
View
MLD-Snooping view
Default Level
2: System level
Parameters
interval: Maximum response time for MLD general queries, in units of seconds. The effective range is 1
to 25.
Description
Use the max-response-time command to configure the maximum response time for MLD general
queries globally.
Use the undo max-response-time command to restore the system default.
By default, the maximum response time for MLD general queries is 10 seconds.
This command works only on MLD snooping–enabled VLANs.
Related commands: mld-snooping max-response-time, mld-snooping query-interval.
Examples
# Set the maximum response time for MLD general queries globally to 5 seconds.
<Sysname> system-view
[Sysname] mld-snooping
[Sysname-mld-snooping] max-response-time 5
mld-snooping
Syntax
mld-snooping
undo mld-snooping
View
System view
Default Level
2: System level

Table of Contents

Other manuals for H3C S3100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3100 Series and is the answer not in the manual?

H3C S3100 Series Specifications

General IconGeneral
BrandH3C
ModelS3100 Series
CategorySwitch
LanguageEnglish

Related product manuals