1-9
poe temperature-protection
Syntax
poe temperature-protection enable
undo poe temperature-protection enable
View
System view
Parameter
None
Description
Use the poe temperature-protection enable command to enable PoE over-temperature protection on
the switch.
Use the undo poe temperature-protection enable command to disable PoE over-temperature
protection on the switch.
The PoE over-temperature protection operates as follows:
The switch disables the PoE feature on all ports when its internal temperature exceeds 65°C (149°F) for
self-protect, and restores the PoE feature settings on all its ports when the temperature drops below
60°C (140°F).
By default, PoE over-temperature protection is enabled on the switch.
You can use the display poe temperature-protection command to display whether PoE
over-temperature protection is enabled on the switch.
Example
# Disable PoE over-temperature protection on the switch.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] undo poe temperature-protection enable
The temperature protection is disabled.
poe update
Syntax
poe update { refresh | full } filename
View
System view
Parameter
refresh: The refresh update mode is used when the PSE processing software is available. The refresh
update mode is to upgrade the original processing software in the PSE.

Table of Contents

Other manuals for H3C S3100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3100 Series and is the answer not in the manual?

H3C S3100 Series Specifications

General IconGeneral
BrandH3C
ModelS3100 Series
CategorySwitch
LanguageEnglish

Related product manuals