Page #1110 background imageLoading...
Page #1110 background image
1-18
View
System view
Parameters
count: Number of the LLDPDUs to be sent successively when a new neighboring device is detected.
This argument ranges from 1 to 10.
Description
Use the lldp fast-count command to set the number of the LLDPDUs to be sent successively when a
new neighboring device is detected.
Use the undo lldp fast-count command to restore the default.
By default, the number is 3.
Examples
# Configure to send four LLDP successively when a new neighboring device is detected.
<Sysname> system-view
[Sysname] lldp fast-count 4
lldp hold-multiplier
Syntax
lldp hold-multiplier value
undo lldp hold-multiplier
View
System view
Parameters
value: TTL multiplier, in the range 2 to 10.
Description
Use the lldp hold-multiplier command to set the TTL multiplier.
Use the undo lldp hold-multiplier command to restore the default.
The TTL multiplier defaults to 4.
You can set the TTL of the local device information by configuring the TTL multiplier.
The TTL of the information about a device is determined by the following expression:
TTL multiplier × LLDPDU transmit interval
You can set the TTL of the local device information by configuring the TTL multiplier. Note that the TTL
can be up to 65535 seconds. TTLs longer than it will be rounded off to 65535 seconds.
Related commands: lldp timer tx-interval.
Examples
# Set the TTL multiplier to 6.
<Sysname> system-view

Table of Contents

Other manuals for H3C S3100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3100 Series and is the answer not in the manual?

H3C S3100 Series Specifications

General IconGeneral
BrandH3C
ModelS3100 Series
CategorySwitch
LanguageEnglish

Related product manuals