Page #1166 background image
1-10
oam errored-frame period
Syntax
oam errored-frame period period-value
undo oam errored-frame period
View
System view
Default Level
2: System level
Parameters
period-value: Errored frame detection interval, ranging from 1 to 60 (in seconds).
Description
Use the oam errored-frame period command to set the errored frame detection interval.
Use the undo oam errored-frame period command to restore the default.
By default, the errored frame detection interval is one second.
Related commands: oam errored-frame threshold, display oam link-event, display oam
configuration.
Examples
# Set the errored frame detection interval to 10 seconds.
<Sysname> system-view
[Sysname] oam errored-frame period 10
oam errored-frame threshold
Syntax
oam errored-frame threshold threshold-value
undo oam errored-frame threshold
View
System view
Default Level
2: System level
Parameters
threshold-value: Errored frame event triggering threshold, ranging from 0 to 4294967295.
Description
Use the oam errored-frame threshold command to set the errored frame event triggering threshold.
Use the undo oam errored-frame threshold command to restore the default.

Table of Contents

Other manuals for H3C S3100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3100 Series and is the answer not in the manual?

H3C S3100 Series Specifications

General IconGeneral
BrandH3C
ModelS3100 Series
CategorySwitch
LanguageEnglish

Related product manuals