1-4
In networking, the following GARP timer settings are recommended:
z GARP hold timer: 100 centiseconds (1 second)
z GARP Join timer: 600 centiseconds (6 seconds)
z GARP Leave timer: 3000 centiseconds (30 seconds)
Related commands: display garp timer.
Examples
# Set the GARP Join timer to 30 centiseconds for Ethernet1/0/1.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] interface Ethernet 1/0/1
[Sysname-Ethernet1/0/1] garp timer join 30
garp timer leaveall
Syntax
garp timer leaveall timer-value
undo garp timer leaveall
View
System view
Parameters
timer-value: Setting (in centiseconds) of the GARP LeaveAll timer. You need to set this argument with
the Leave timer settings of other Ethernet ports as references. That is, this argument needs to be larger
than the Leave timer settings of any Ethernet ports. Also note that this argument needs to be a multiple
of 5 and cannot be larger than 32,765.
Description
Use the garp timer leaveall command to set the GARP LeaveAll timer.
Use the undo garp timer leaveall command to restore the default setting of the GARP LeaveAll timer.
By default, the LeaveAll timer is set to 1,000 centiseconds, that is, 10 seconds.
In networking, you are recommended to set the GARP LeaveAll timer to 12000 centiseconds (2
minutes).
Related commands: display garp timer.

Table of Contents

Other manuals for H3C S3100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3100 Series and is the answer not in the manual?

H3C S3100 Series Specifications

General IconGeneral
BrandH3C
ModelS3100 Series
CategorySwitch
LanguageEnglish

Related product manuals