3-9
Field Remarks
Temp high Temperature is high.
Temp low Temperature is low.
Transceiver info I/O error Transceiver information read and write error
Transceiver info checksum error Transceiver information checksum error
Transceiver type and port configuration
mismatch
Transceiver type does not match port configuration.
Transceiver type not supported by port
hardware
Transceiver type is not supported on the port.
For pluggable transceivers supported by S3100 series Ethernet switches, refer to H3C S3100 Series
Ethernet Switches Installation Manual.
Examples
# Display the alarm information of the transceiver on interface GigabitEthernet 1/1/2.
<Sysname> display transceiver alarm interface gigabitethernet 1/1/2
GigabitEthernet1/1/2 transceiver current alarm information:
TX fault
Table 3-6 Description on the fields of display transceiver alarm interface
Field Description
transceiver current alarm information Current alarm information of the transceiver
TX fault TX fault
display transceiver diagnosis interface
Syntax
display transceiver diagnosis interface [ interface-type interface-number ]
View
Any view
Parameters
interface-type interface-number: Interface type and interface number.
Description
Use the display transceiver diagnosis interface command to display the currently measured value of
digital diagnosis parameters of a single or all anti-spoofing transceivers customized by H3C.