local: Displays the statistics on the local Ethernet OAM link error events.
remote: Displays the statistics on the peer Ethernet OAM link error events.
interface interface-type interface-number: Specify a port by its type and number.
Description
Use the display oam link-event command to display the statistics on Ethernet OAM link error events
occurred on a local port or a peer port. Ethernet OAM link error events include errored symbol events,
errored frame events, errored frame period events, and errored frame seconds events.
If you do not specify the interface keyword, this command displays the statistics on the Ethernet
OAM link error events occurred on all the local/peer ports.
Related commands: display oam configuration, reset oam.
Examples
# Display the statistics on Ethernet OAM link error events occurred on all the local ports.
<Sysname> display oam link-event local
Port : Ethernet1/0/1
Link Status : Up
OAMLocalErrFrameEvent : (ms = milliseconds)
--------------------------------------------------------------------------
Event Time Stamp : 3539 Errored Frame Window : 10(100ms)
Errored Frame Threshold : 5 Errored Frame : 1488111
Error Running Total : 260908758 Event Running Total : 307
OAMLocalErrFramePeriodEvent :
--------------------------------------------------------------------------
Event Time Stamp : 3539 Errored Frame Window : 976500
Errored Frame Threshold : 1 Errored Frame : 1042054
Error Running Total : 260909151 Event Running Total : 471
OAMLocalErrFrameSecsSummaryEvent : (ms = milliseconds)
--------------------------------------------------------------------------
Event Time Stamp : 3389
Errored Frame Second Summary Window : 600(100ms)
Errored Frame Second Summary Threshold : 1
Errored Frame Second Summary : 60
Error Running Total : 292 Event Running Total : 5

Table of Contents

Other manuals for H3C S3100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3100 Series and is the answer not in the manual?

H3C S3100 Series Specifications

General IconGeneral
BrandH3C
ModelS3100 Series
CategorySwitch
LanguageEnglish

Related product manuals