1-18
history-records
Syntax
history-records number
undo history-records
View
HWPing test group view
Parameters
Number: Maximum number of history records that can be saved in a test group, in the range of 0 to 50,
and 50 by default.
Description
Use the history-records command to set the maximum number of history records that can be saved in
a test group.
Use the undo history-records to restore the default.
By default, up to 50 records can be saved in a test group.
Examples
# Set the maximum number of history records that can be saved to 10.
<Sysname> system-view
System View: return to User View with Ctrl+Z
[Sysname] hwping administrator icmp
[Sysname-hwping-administrator-icmp] test-type icmp
[Sysname-hwping-administrator-icmp] history-records 10
http-operation
Syntax
http-operation { get | post }
View
HWPing test group view
Parameters
get: Specifies the test operation to be download from the HTTP server.
post: Specifies the test operation to be uploaded to the HTTP server.
Description
Use the http-operation command to configure the HTTP operation mode.
By default, the HTTP operation mode is get.
The http-operation command applies to HTTP tests only.
Examples
# Set the HTTP operation mode to post in an HTTP test.

Table of Contents