09/03
2-69
DC 3535/2240/1632, WC M24
4-361, 4-362
Status Indicator RAPs
Initial issue
Figure 2 4-361 RAP Circuit Diagram - Drum Motor (Y,M,C) (DC3535)
4-362 IOT NVM Read Write
Read Write at the MCU PWB NVM R/W.
Procedure
Switch the power off, then on. The problem continues.
YN
Return to Service Call Procedures.
Check the connection between the MCU PWB and the MCU NVM PWB.
If the problem continues, replace the MCU PWB (PL 13.1).
CAUTION
Careful replacement of the MCU NVM PWB (REP 1.15) is important to avoid serious machine
failure.
If the problem continues, replace the MCU NVM PWB (PL 13.1).