09/03
2-674
DC 3535/2240/1632, WC M24
116-395, 116-396
Initial issue
Status Indicator RAPs
116-395 USB Software
Fatal error related to USB. Due to an error during the software processing, the subsequent pro-
cesses cannot be performed.
Initial Actions
Switch power off then on. If the problem persists, continue with the procedure.
Procedure
Perform GP 3. If the problem continues, reload system software. If the problem persists,
replace the ESS PWB (PL 13.1).
116-396 Mail IO Software
Fatal error related to Mail IO. Due to an error during the software processing, the subsequent
processes cannot be performed.
Initial Actions
Switch power off then on. If the problem persists, continue with the procedure.
Procedure
Perform GP 3. If the problem continues, reload system software. If the problem persists,
replace the ESS PWB (PL 13.1).