09/03
2-675
DC 3535/2240/1632, WC M24
116-398, 116-399
Status Indicator RAPs
Initial issue
116-398 IPP Software
Fatal error related to IPP
Due to an error during the software processing, the subsequent processes cannot be per-
formed.
Initial Actions
Switch power off then on. If the problem persists, continue with the procedure.
Procedure
Perform GP 3. If the problem continues, reload system software. If the problem persists,
replace the ESS PWB (PL 13.1).
116-399 JME Software
Fatal error related to JME
Due to an error during the software processing, the subsequent processes cannot be per-
formed.
Initial Actions
Switch power off then on. If the problem persists, continue with the procedure.
Procedure
Perform GP 3. If the problem continues, reload system software. If the problem persists,
replace the ESS PWB (PL 13.1).