09/03
2-668
DC 3535/2240/1632, WC M24
116-374, 116-375
Initial issue
Status Indicator RAPs
116-374 Auto Switch
Fatal error of Auto SW. Due to an error during the software processing, the subsequent pro-
cesses cannot be performed.
Initial Actions
Switch power off then on. If the problem persists, continue with the procedure.
Procedure
Perform GP 3. If the problem continues, reload system software. If the problem persists,
replace the ESS PWB (PL 13.1).
116-375 I-Formatter
Formatter problem.
Initial Actions
Switch power off then on. If the problem persists, continue with the procedure.
Procedure
Perform GP 3. If the problem continues, reload system software. If the problem persists,
replace the ESS PWB (PL 13.1).