Status Indicator RAPs
16-705 Security Storage without HD
Registry for Secure Print has failed because Security Storage cannot be done due to no HDD
available.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Check HDD (PL 13.1) harness connection.
If the problem occurred at installation, check whether the operations for Secure Print are cor-
rect.
16-706 Maximum User Number
The system detected that a job exceeded the maximum number of users for Secure and Proof
Prints and aborted the job. Full status was detected at HDD access and a job was aborted.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Delete unwanted documents/users and retry printing.