09/03
2-172
DC 3535/2240/1632, WC M24
8-625, 8-626
Initial issue
Status Indicator RAPs
8-625 Regicon Sample Block (A1 Patch-rear)
At A1 (IN) patch detection, the number of the sample blocks does not reach the specified num-
ber.
NOTE: Status Code not displayed on UI. Machine operation continues.
Procedure
Check the IBT Belt and Drum for a scratch or contamination. The check is OK.
YN
Replace as required.
Adjust the Color Registration (ADJ 9.6).
8-626 Regicon Sample Block (A1 Patch-front)
At A1 (OUT) patch detection, the number of the sample blocks does not reach the specified
number.
NOTE: Status Code not displayed on UI. Machine operation continues.
Procedure
Check the IBT Belt and Drum for a scratch or contamination. The check is OK.
YN
Replace as required.
Adjust the Color Registration (ADJ 9.6).