09/03
4-165
DC 3535/2240/1632, WC M24
ADJ 9.1
Repairs and Adjustments
Initial issue
ADJ 9.1 Max Setup
Purpose
To conduct a check of the machine and set it up so that excellent copy quality can be consis-
tently obtained by stabilizing the development potential and copy density.
Adjustment
Max Setup consists of 5 separate adjustments that should be performed in the following
sequence:
1. ADJ 9.7, IIT Calibration (dC945)
NOTE: Perform ADJ 9.2 only when replacing the ATC Sensor or Developer Housing.
2. ADJ 9.2, ATC Sensor Setup (dC921)
3. ADJ 9.3, TRC Control/Toner Density Setup (dC922)
4. ADJ 9.4, ADC Output (dC934)
NOTE: Perform ADJ 9.5 only when the customer requests.
5. ADJ 9.5, Manual TRC Adjust (dC924)